Jaspering Electric, Inc.: OSHA inspections and violations
Ames, Iowa · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210
10inspections
11citation items
$3,214current penalties
Aug 26, 2021last inspection
OSHA has inspected Jaspering Electric, Inc. 10 times in Iowa since 2003.
The latest one began on Aug 26, 2021, in Ames.
Those inspections ended with 11 citation items: 4 serious and 7 other-than-serious.
Penalties were first proposed at $6,427 and now stand at $3,214, 50% lower after settlements or reviews.
Electrical equipment on job sites comes up most often in these citations: 4 items under 1926.403.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Jaspering Electric, Inc. averages $2,088 (1 cited inspection).
Jaspering Electric, Inc. also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Iowa · latest 90 days of OSHA records
69employers cited
Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Ames site logged 0 recordable injuries or illnesses among about 65 workers: 0.0 per 100 full-time workers, against a median of 1.8 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Jaspering Electric Inc.
Ames · 2025
65
0
0
0.0
1.8
Included with any plan: 7 more yearly logs from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and
(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.
29 CFR 1926.403(h)
(h) Identification of disconnecting means and circuits. Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. These markings shall be of sufficient durability to withstand the environment involved.
Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.