OSHA SearchOSHA records by employer

Javier Vento: OSHA inspections and violations

Mission, Texas · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
3citation items
$9,236current penalties
Jan 24, 2017last inspection

OSHA has inspected Javier Vento once in Texas.

The inspection began on Jan 24, 2017 as a planned inspection, in Mission.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $9,236 and still stand at $9,236.

Excavations comes up most often in these citations: 2 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,078, and Javier Vento averages $9,236 (1 cited inspection).

Javier Vento: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Javier Vento again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342054053 OPENED JAN 24, 2017Closed

Planned · Partial · Safety · 3 employees at the site · Closed Sep 7, 2022

N. Conway Ave & W. Griffin Pkwy, Mission, TX 78572 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$3,803$3,803Jul 11, 2017Final
Citation 1, item 2
29 CFR 1926.651(k)(1) · Excavations
Serious$1,630$1,630Jul 11, 2017Final
Citation 1, item 3
29 CFR 1926.652(a)(1) · Trench protection
Serious$3,803$3,803Jul 11, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

Other water and sewer line and related structures construction employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.