OSHA SearchOSHA records by employer

Jaw Contracting, LLC: OSHA inspections and violations

Bethlehem, Pennsylvania · Roofing Contractors · NAICS 238160

3inspections
7citation items
$25,677current penalties
Jun 28, 2019last inspection

Jaw Contracting, LLC has 3 OSHA inspections on record in Pennsylvania, the first in 2018.

OSHA's last visit started on Jun 28, 2019 after a complaint, in Emmaus.

Across those inspections OSHA issued 7 citation items: 4 serious and 3 repeat.

OSHA proposed $25,677 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.1053, ladders in construction (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Jaw Contracting, LLC averages $8,559 over 3 cited inspections in that time.

Jaw Contracting, LLC: OSHA citation items per year, 2018 to 2019
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

297employers cited

30 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Jaw Contracting, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344127154 OPENED JUN 28, 2019Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Apr 3, 2023

752 Frank Dr, Emmaus, PA 18049 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$8,752$8,752Aug 30, 2019Final
Citation 1, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Repeat$7,502$7,502Aug 30, 2019Final
Citation 1, item 2b
29 CFR 1926.1053(b)(16) · Ladders in construction
Repeat$0$0Aug 30, 2019Final

Inspection 343378154 OPENED AUG 10, 2018Closed

Unprogrammed related · Partial · Safety · 5 employees at the site · Closed Dec 6, 2022

Quality Inn & Suites 3671 Street Road, Bensalem, PA 19020 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(vi) · Fire protection
Serious$2,217$2,217Sep 21, 2018Final

Inspection 343278347 OPENED JUL 5, 2018Closed

Planned · Partial · Safety · 5 employees at the site · Closed Nov 14, 2022

1421 W. Union Blvd., Bethlehem, PA 18018 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,880$3,880Jul 18, 2018Final
Citation 1, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,326$3,326Jul 18, 2018Final
Citation 1, item 2b
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Jul 18, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(vi)

(vi) A fire extinguisher, rated not less than 10B, shall be provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite. This requirement does not apply to the integral fuel tanks of motor vehicles.

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.