OSHA SearchOSHA records by employer

JC Masonry LLC: OSHA inspections and violations

Houston, Texas · Masonry Contractors · NAICS 238140

2inspections
4citation items
$10,930current penalties
Dec 6, 2022last inspection

Since 2011, OSHA inspectors have visited JC Masonry LLC in Texas 2 times.

The most recent inspection opened on Dec 6, 2022 as a planned inspection, in Magnolia.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $13,416; today they stand at $10,930, 19% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. JC Masonry LLC averages $3,730 across 1 cited inspection.

JC Masonry LLC: OSHA citation items per year, 2011 to 2022
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch JC Masonry LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346375025 OPENED DEC 6, 2022Closed

Planned · Partial · Safety · 8 employees at the site · Closed Jan 2, 2024

13650 Fm 1488, Magnolia, TX 77354 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,108$1,865Jan 3, 2023Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,108$1,865Jan 3, 2023Final

Inspection 315722736 OPENED SEP 15, 2011Closed

Unprogrammed other · Complete · Safety · 18 employees at the site · Closed May 15, 2016

11805 Meadow Glen Lane, Houston, TX 77082 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,000$3,000Oct 4, 2011Closed
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$4,200$4,200Oct 4, 2011Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.