JC Roofing Inc.: OSHA inspections and violations

San Marcos, Texas · Roofing Contractors · NAICS 238160

1inspections
3citation items
$3,108current penalties
Apr 16, 2015last inspection

JC Roofing Inc. has one OSHA inspection on record in Texas.

OSHA opened it on Apr 16, 2015 as a planned inspection, in San Marcos.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $5,180 in penalties. After settlements and reviews the total is $3,108, down 40%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. JC Roofing Inc. averages $3,108 over 1 cited inspection in that time.

JC Roofing Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

394employers cited

48 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch JC Roofing Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340560713 OPENED APR 16, 2015Closed

Planned · Partial · Safety · 8 employees at the site · Closed Sep 13, 2016

108 Ih-35 North, San Marcos, TX 78666 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring
Serious$1,020$612May 27, 2015Final
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,800$1,680May 27, 2015Final
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,360$816May 27, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(i)

(iii) Guarding. For temporary wiring over 600 volts, nominal, fencing, barriers, or other effective means shall be provided to prevent access of other than authorized and qualified personnel.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

Other roofing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.