Inspection 343150801 OPENED MAY 9, 2018Closed
Joeten Kagman Village Of Kagman, Saipan, MP 96950 · General Merchandise Stores · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Saipan, Northern Mariana Islands · General Merchandise Stores · NAICS 452990
OSHA has inspected JC Tenorio Enterprises, Inc. 5 times in Northern Mariana Islands since 2004.
The latest one began on May 9, 2018 as a planned inspection, in Saipan.
Those inspections ended with 6 citation items: 2 serious and 4 other-than-serious.
Penalties were first proposed at $5,990 and now stand at $3,968, 34% lower after settlements or reviews.
Job-site wiring comes up most often in these citations: 4 items under 1926.405.
How that compares: the median penalty per cited inspection for retail employers since 2015 is $2,130, and JC Tenorio Enterprises, Inc. averages $2,968 (1 cited inspection).
Northern Mariana Islands · latest 90 days of OSHA records
7employers cited
Get notified the morning OSHA posts each new citation in Northern Mariana Islands: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Northern Mariana Islands
Checking a subcontractor, a client or your own company? Watch JC Tenorio Enterprises, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this companyJoeten Kagman Village Of Kagman, Saipan, MP 96950 · General Merchandise Stores · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Joeten Dandan Market Airport Road, Saipan, MP 96950 · General Merchandise Stores · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Joeten Garapan Store Warehoue Hafa Adai Shopping Center, Saipan, MP 96950 · General Merchandise Stores · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Jc Building, Beach Road Village Of Susupe, Saipan, MP 96950 · General Merchandise Stores · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.28(b)(11)(ii) · Fall protection in general industry |
Serious | $4,240 | $2,968 | Jul 19, 2018 | Final |
Jc Building, Beach Road, Saipan, MP 96950 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(b)(1) · Job-site wiring |
Other-than-serious | $750 | $0 | Jun 25, 2004 | Final |
| Citation 1, item 2a 29 CFR 1926.405(g)(1)(iii) · Job-site wiring |
Serious | $1,000 | $1,000 | Jun 25, 2004 | Final |
| Citation 1, item 2c 29 CFR 1926.405(g)(2)(iv) · Job-site wiring |
Other-than-serious | $0 | $0 | Jun 25, 2004 | Final |
| Citation 1, item 2d 29 CFR 1926.405(g)(2)(v) · Job-site wiring |
Other-than-serious | $0 | $0 | Jun 25, 2004 | Final |
| Citation 2, item 2 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Other-than-serious | $0 | $0 | Jun 25, 2004 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.28(b)(11)(ii)
(ii) Each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as follows:
29 CFR 1926.404(b)(1)(i)
(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.
29 CFR 1926.405(b)(1)
(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.