Jca Construction: OSHA inspections and violations

Centerville, Utah · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
3citation items
$0current penalties
May 5, 2020last inspection

Jca Construction has one OSHA inspection on record in Utah.

OSHA opened it on May 5, 2020 as a planned inspection, in Centerville.

From that inspection OSHA issued 3 citation items: 3 other-than-serious.

OSHA did not attach a penalty to any of these citations.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,078. Jca Construction averages $0 over 1 cited inspection in that time.

Jca Construction: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites Jca Construction again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344742465 OPENED MAY 5, 2020Closed

Planned · Partial · Safety · 3 employees at the site · Closed Aug 10, 2020

300 East Pages Ln, Centerville, UT 84014 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$0$0Jun 11, 2020Final
Citation 1, item 1b
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Other-than-serious$0$0Jun 11, 2020Final
Citation 1, item 1c
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Other-than-serious$0$0Jun 11, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iii)

(iii) Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

Other new single-family housing construction (except for-sale builders) employers in Utah

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.