OSHA SearchOSHA records by employer

JCL Masonry, LLC: OSHA inspections and violations

Upper Marlboro, Maryland · Masonry Contractors · NAICS 238140

3inspections
14citation items
$8,500current penalties
Oct 24, 2019last inspection

Since 2014, OSHA inspectors have visited JCL Masonry, LLC in Maryland 3 times.

The most recent inspection opened on Oct 24, 2019, in White Plains.

In all, OSHA issued 14 citation items: 11 serious and 3 repeat.

The proposed penalties came to $11,875; today they stand at $8,500, 28% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 11 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. JCL Masonry, LLC averages $3,750 across 2 cited inspections.

JCL Masonry, LLC: OSHA citation items per year, 2014 to 2019
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

194employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch JCL Masonry, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344398763 OPENED OCT 24, 2019Closed

Unprogrammed other · Complete · Safety · 6 employees at the site · Closed May 18, 2021

11275-11281 St. Lukes Drive, White Plains, MD 20695 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$1,050$756Apr 3, 2020Final
Citation 1, item 2
29 CFR 1926.50(g) · Medical services and first aid
Serious$750$473Apr 3, 2020Final
Citation 1, item 3a
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$450$365Apr 3, 2020Final
Citation 1, item 3b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Apr 3, 2020Final
Citation 2, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Repeat$4,800$3,456Apr 3, 2020Final

Inspection 341569606 OPENED JUN 22, 2016Closed

Planned · Complete · Safety · 6 employees at the site · Closed Sep 13, 2016

8721 Wellford Dr., Ellicott City, MD 21042 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$225$182Aug 16, 2016Final
Citation 1, item 1b
29 CFR 1926.451(e)(5)(i) · Scaffolds, general requirements
Serious$0$0Aug 16, 2016Final
Citation 2, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Repeat$2,800$1,764Aug 16, 2016Final
Citation 3, item 1
29 CFR 1926.451(e)(9)(iv) · Scaffolds, general requirements
Repeat$800$504Aug 16, 2016Final

Inspection 317772440 OPENED JUL 10, 2014Closed

Planned · Complete · Safety · 7 employees at the site · Closed Oct 5, 2015

4406 Cross Country Way, Upper Marlboro, MD 20772 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$1,000$1,000Aug 18, 2014Closed
Citation 1, item 1b
29 CFR 1926.451(e)(9)(iv) · Scaffolds, general requirements
Serious$0$0Aug 18, 2014Closed
Citation 1, item 1c
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Aug 18, 2014Closed
Citation 1, item 1d
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Aug 18, 2014Closed
Citation 1, item 1e
29 CFR 1926.454(c)(3) · Scaffold training
Serious$0$0Aug 18, 2014Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(g)(1)

(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.454 · Scaffold training

29 CFR 1926.50 · Medical services and first aid

Other masonry contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.