OSHA SearchOSHA records by employer

JCM Home Solutions LLC: OSHA inspections and violations

Williamsburg, Virginia · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
3citation items
$1,239current penalties
Jan 7, 2026last inspection

OSHA has inspected JCM Home Solutions LLC once in Virginia.

The inspection began on Jan 7, 2026, in Williamsburg.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $1,770 and now stand at $1,239, 30% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and JCM Home Solutions LLC averages $1,239 (1 cited inspection).

JCM Home Solutions LLC: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

246employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch JCM Home Solutions LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348673542 OPENED JAN 7, 2026Closed

Unprogrammed other · Complete · Safety · 5 employees at the site · Closed Jul 29, 2026

39 Winster Fax, Williamsburg, VA 23188 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$720$504Jun 2, 2026Final
Citation 1, item 2a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,050$735Jun 2, 2026Final
Citation 1, item 2b
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Jun 2, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

Other new single-family housing construction (except for-sale builders) employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.