OSHA SearchOSHA records by employer

Jefferson Cocke County Utility District - Operations Department: OSHA inspections and violations

Newport, Tennessee · Natural Gas Distribution · NAICS 221210

2inspections
8citation items
$0current penalties
Jul 9, 2019last inspection

Since 2017, OSHA inspectors have visited Jefferson Cocke County Utility District - Operations Department in Tennessee 2 times.

The most recent inspection opened on Jul 9, 2019 as a planned inspection, in Newport.

In all, OSHA issued 8 citation items: 8 serious.

No penalty came with these citations.

Among utility employers, the typical cited inspection since 2015 ends with a $0 penalty. Jefferson Cocke County Utility District - Operations Department averages $0 across 2 cited inspections.

Jefferson Cocke County Utility District - Operations Department: OSHA citation items per year, 2017 to 2019
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

321employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Jefferson Cocke County Utility District - Operations Department and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344139175 OPENED JUL 9, 2019Closed

Planned · Complete · Safety · Local government · 41 employees at the site · Closed Aug 7, 2019

122 Highway 25 E, Newport, TN 37821 · Natural Gas Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(3)(ii) · Fall protection in general industry
Serious$0$0Jul 24, 2019Final
Citation 1, item 2
29 CFR 1910.29(f)(4) · Fall protection systems in general industry
Serious$0$0Jul 24, 2019Final
Citation 1, item 3
29 CFR 1910.37(b)(2) · Exit routes
Serious$0$0Jul 24, 2019Final
Citation 1, item 4
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Serious$0$0Jul 24, 2019Final
Citation 1, item 5
29 CFR 1910.305(g)(1)(iv)(b) · Electrical wiring methods
Serious$0$0Jul 24, 2019Final
Citation 1, item 6
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$0$0Jul 24, 2019Final

Inspection 342656576 OPENED SEP 21, 2017Closed

Planned · Complete · Safety · Local government · 43 employees at the site · Closed Oct 30, 2018

122 Highway 25 E, Newport, TN 37821 · Natural Gas Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(j)(2) · Overhead and gantry cranes
Serious$0$0Oct 4, 2017Final
Citation 1, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Oct 4, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(3)

(3) The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.179(j)(2)

(2) Frequent inspection. The following items shall be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections. All deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard:

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.215(b)(9)

(9) Exposure adjustment. Safety guards of the types described in subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b) (3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.)

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.29 · Fall protection systems in general industry

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.37 · Exit routes

Other natural gas distribution employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.