OSHA SearchOSHA records by employer

Jeffrey Construction: OSHA inspections and violations

Bel Air, Maryland · Framing Contractors · NAICS 238130

1inspections
4citation items
$375current penalties
Oct 30, 2017last inspection

OSHA inspectors have visited Jeffrey Construction in Maryland one time.

It opened on Oct 30, 2017 as a planned inspection, in Bel Air.

In all, OSHA issued 4 citation items: 1 serious and 3 other-than-serious.

The penalties, $375 in total, stand where OSHA first set them.

The rule cited most here is 1926.404 (ground-fault protection on job sites), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Jeffrey Construction averages $375 across 1 cited inspection.

Jeffrey Construction: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Jeffrey Construction again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342740339 OPENED OCT 30, 2017Closed

Planned · Complete · Safety · 4 employees at the site · Closed Feb 15, 2018

523 Underwood Lane, Bel Air, MD 21014 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(15) · Fall protection in construction
Serious$375$375Jan 18, 2018Final
Citation 2, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Other-than-serious$0$0Jan 18, 2018Final
Citation 2, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Jan 18, 2018Final
Citation 2, item 3
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Jan 18, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(15)

(15) Walking/working surfaces not otherwise addressed. Except as provided in § 1926.500(a)(2) or in § 1926.501 (b)(1) through (b)(14), each employee on a walking/working surface 6 feet (1.8 m) or more above lower levels shall be protected from falling by a guardrail system, safety net system, or personal fall arrest system.

29 CFR 1926.503 · Fall protection training in construction

Other framing contractors employers in Maryland

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.