OSHA SearchOSHA records by employer

Jerry Rich: OSHA inspections and violations

Brunswick, Georgia · Roofing Contractors · NAICS 238160

1inspections
6citation items
$4,434current penalties
Feb 15, 2018last inspection

Jerry Rich has one OSHA inspection on record in Georgia.

OSHA opened it on Feb 15, 2018 as a planned inspection, in Brunswick.

From that inspection OSHA issued 6 citation items: 6 serious.

OSHA proposed $8,869 in penalties. After settlements and reviews the total is $4,434, down 50%.

Most often, OSHA cited 1926.454, scaffold training (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Jerry Rich averages $4,434 over 1 cited inspection in that time.

Jerry Rich: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

142employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Jerry Rich and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342961349 OPENED FEB 15, 2018Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jul 13, 2018

37 Millpond Circle, Brunswick, GA 31525 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,217$1,108May 11, 2018Final
Citation 1, item 2a
29 CFR 1926.451(b)(2)(i) · Scaffolds, general requirements
Serious$3,326$1,663May 11, 2018Final
Citation 1, item 2b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0May 11, 2018Final
Citation 1, item 2c
29 CFR 1926.452(k)(2) · Rules for each type of scaffold
Serious$0$0May 11, 2018Final
Citation 1, item 3a
29 CFR 1926.454(a) · Scaffold training
Serious$3,326$1,663May 11, 2018Final
Citation 1, item 3b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0May 11, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)(i)

(i) Each ladder jack scaffold, top plate bracket scaffold, roof bracket scaffold, and pump jack scaffold shall be at least 12 inches (30 cm) wide. There is no minimum width requirement for boatswains' chairs.

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other roofing contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.