OSHA SearchOSHA records by employer

Jesus Villegas: OSHA inspections and violations

Fort Worth, Texas · Framing Contractors · NAICS 238130

3inspections
22citation items
$23,030current penalties
May 27, 2021last inspection

OSHA has inspected Jesus Villegas 3 times in Texas since 2001.

The latest one began on May 27, 2021 as a planned inspection, in Corpus Christi.

Those inspections ended with 22 citation items: 21 serious and 1 other-than-serious.

Penalties were first proposed at $34,130 and now stand at $23,030, 33% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 17 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Jesus Villegas averages $14,630 (1 cited inspection).

Jesus Villegas: OSHA citation items per year, 2001 to 2021
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

55 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Jesus Villegas and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345332555 OPENED MAY 27, 2021Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jan 6, 2026

3100 Santa Fe St, Corpus Christi, TX 78404 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$2,926$2,926Jul 7, 2021Final
Citation 1, item 2
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$2,926$2,926Jul 7, 2021Final
Citation 1, item 3
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,926$2,926Jul 7, 2021Final
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,926$2,926Jul 7, 2021Final
Citation 1, item 5
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,926$2,926Jul 7, 2021Final
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Other-than-serious$0$0Jul 7, 2021Final

Inspection 110038643 OPENED OCT 24, 2001Closed

Unprogrammed related · Partial · Safety · 6 employees at the site · Closed May 1, 2007

650 E. Vista Ridge Mall Dr., Lewisville, TX 75067 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$1,000$1,000Dec 14, 2001Closed
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,000$1,000Dec 14, 2001Closed
Citation 1, item 3
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,000$1,000Dec 14, 2001Closed
Citation 1, item 4
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$1,000$1,000Dec 14, 2001Closed
Citation 1, item 5
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$1,000$1,000Dec 14, 2001Closed
Citation 1, item 6
29 CFR 1926.454(b) · Scaffold training
Serious$1,000$1,000Dec 14, 2001Closed

Inspection 304267339 OPENED JUL 25, 2001Closed

Unprogrammed other · Partial · Safety · 9 employees at the site · Closed Sep 13, 2002

4699 Fossil Vista, Fort Worth, TX 76137 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$1,500$267Sep 14, 2001Closed
Citation 1, item 1b
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$0$0Sep 14, 2001Closed
Citation 1, item 2
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$1,500$267Sep 14, 2001Closed
Citation 1, item 3
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,500$267Sep 14, 2001Closed
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,500$267Sep 14, 2001Closed
Citation 1, item 5
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,500$267Sep 14, 2001Closed
Citation 1, item 6
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$1,500$267Sep 14, 2001Closed
Citation 1, item 7
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,500$267Sep 14, 2001Closed
Citation 1, item 8
29 CFR 1926.454(a) · Scaffold training
Serious$1,500$267Sep 14, 2001Closed
Citation 1, item 9
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$264Sep 14, 2001Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.