OSHA SearchOSHA records by employer

Jev Construction LLC.: OSHA inspections and violations

Pine Grove, Pennsylvania · Commercial and Institutional Building Construction · NAICS 236220

2inspections
3citation items
$8,512current penalties
May 19, 2025last inspection

Since 2019, OSHA inspectors have visited Jev Construction LLC. in Pennsylvania 2 times.

The most recent inspection opened on May 19, 2025 after a complaint, in Chambersburg and is still open.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $8,512 in total, stand where OSHA first set them.

The rule cited most here is 1926.1053 (ladders in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Jev Construction LLC. averages $8,512 across 1 cited inspection.

Jev Construction LLC.: OSHA citation items per year, 2019 to 2025
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

299employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Jev Construction LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348254269 OPENED MAY 19, 2025Open

Complaint · Partial · Safety · 3 employees at the site · Open

541 Gateway Avenue, Chambersburg, PA 17201 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$4,965$4,965Jul 10, 2025Final
Citation 1, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,547$3,547Jul 10, 2025Final
Citation 1, item 2b
29 CFR 1926.1053(b)(10) · Ladders in construction
Serious$0$0Jul 10, 2025Final

Inspection 343993242 OPENED MAY 9, 2019Closed

Planned · No inspection · Safety · Closed May 9, 2019

Pine Grove, PA 17963 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(10)

(10) The top of a non-self-supporting ladder shall be placed with the two rails supported equally unless it is equipped with a single support attachment.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

Other commercial and institutional building construction employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.