OSHA SearchOSHA records by employer

JFM International, Inc.: OSHA inspections and violations

Willis, Texas · Lumber, Plywood, Millwork, and Wood Panel Merchant Wholesalers · NAICS 423310

4inspections
24citation items
$40,386current penalties
Oct 15, 2020last inspection

Since 2013, OSHA inspectors have visited JFM International, Inc. in Texas 4 times.

The most recent inspection opened on Oct 15, 2020 on a referral, in Willis.

In all, OSHA issued 24 citation items: 20 serious, 1 repeat and 3 other-than-serious.

The proposed penalties came to $125,975; today they stand at $40,386, 68% less.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 5 times.

Among wholesale employers, the typical cited inspection since 2015 ends with a $3,425 penalty. JFM International, Inc. averages $13,462 across 3 cited inspections.

JFM International, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 4 severe injuries to OSHA since 2015.

JFM International, Inc.: OSHA citation items per year, 2013 to 2020
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

401employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch JFM International, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344977152 OPENED OCT 15, 2020Closed

Referral · Partial · Health · 71 employees at the site · Closed Sep 7, 2022

300 East Stewart St., Willis, TX 77378 · Lumber, Plywood, Millwork, and Wood Panel Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Incident on Oct 9, 2020: Employee's fingertip is struck by drill bit, is later amputa

At 11:30 a.m. on October 9, 2020, an employee was working at a firm that made wood cable reels. The employee was an assistant machine operator in training. She was in the north area of the facility, in the wood reels fabrication area. There was a new automatic CNC machine there, a Naliteck model NL 60/125 automated machining center for flanges, with no serial number identified. It had been installed in January 2020. The machining center ran on electricity. It operated on voltages from 220 to 480 volts. For the machine to operate on a continuous basis, employees had to clean up the pieces of wood cut during reel fabrication. The cleaning occurred in station 3, where the machining of flange and chamfering was done. This was a core activity involving a drill bit that cut the external borders of the reels. The drill bit was not guarded. The employee was watching the machine to verify that it was working properly. Without stopping the machine, she was removing pieces of wood from the drill bit with her gloved right hand. Her hand was caught by the drill bit. It was entangled and pulled in. The employee was hospitalized. The wound proved so severe that her fingertip was surgically amputated. Although there were two other employees with her, neither of them witnessed the incident. According to employees, the cleaning occurred approximately twice per day or more times, depending on whether there was a problem with the fabrication process. Whenever the employees were cleaning the area, they were supposed to turn off the machine and use a 6-in. (150-mm) stick to remove the pieces of wood. From the employees' statements, it was a common practice to clean the area of the drill bit located in station 3 without stopping the machine. The employer did not have a written procedure for the cleaning procedure. The operations manager stated that the Naliteck machine was installed brand new in January 2020 and that the drill bit area never had guards. The firm had been previously cited.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Repeat$18,023$8,000Feb 4, 2021Final

Inspection 341787471 OPENED SEP 20, 2016Closed

Referral · Partial · Safety · 90 employees at the site · Closed May 10, 2024

300 E. Stewart St., Willis, TX 77378 · Lumber, Plywood, Millwork, and Wood Panel Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$8,730$2,619Dec 1, 2016Final
Citation 1, item 1b
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$0$0Dec 1, 2016Final
Citation 1, item 2
29 CFR 1910.212(a)(5) · Machine guarding
Serious$6,236$1,871Dec 1, 2016Final
Citation 1, item 3a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$8,730$2,619Dec 1, 2016Final
Citation 1, item 3b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Dec 1, 2016Final
Citation 1, item 4
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$7,482$2,245Dec 1, 2016Final
Citation 1, item 5a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$8,730$2,619Dec 1, 2016Final
Citation 1, item 5b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 1, 2016Final
Citation 1, item 5c
29 CFR 1910.219(m)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 1, 2016Final
Citation 1, item 6
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$8,730$2,619Dec 1, 2016Final
Citation 1, item 7
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$7,482$2,245Dec 1, 2016Final
Citation 1, item 8
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$3,741$1,122Dec 1, 2016Final
Citation 1, item 9
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$4,988$1,496Dec 1, 2016Final
Citation 1, item 10
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$8,730$2,619Dec 1, 2016Final
Citation 2, item 1
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 1, 2016Final
Citation 2, item 2
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Dec 1, 2016Final

Inspection 341777126 OPENED SEP 16, 2016Closed

Complaint · Partial · Health · 90 employees at the site · Closed Apr 22, 2024

300 E. Stewart St., Willis, TX 77378 · All Other Miscellaneous Wood Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$6,236$1,871Dec 1, 2016Final
Citation 1, item 2a
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$8,730$2,619Dec 1, 2016Final
Citation 1, item 2b
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Serious$0$0Dec 1, 2016Final
Citation 1, item 3
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$6,236$1,871Dec 1, 2016Final
Citation 1, item 4
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$8,730$2,619Dec 1, 2016Final
Citation 1, item 5
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$3,741$1,122Dec 1, 2016Final
Citation 2, item 1
29 CFR 1904.29(b)(3) · Injury and illness log
Other-than-serious$700$210Dec 1, 2016Final

Inspection 339413932 OPENED AUG 27, 2013Closed

Complaint · Complete · Safety · 28 employees at the site · Closed Dec 12, 2013

300 E. Stewart St., Willis, TX 77378 · Lumber, Plywood, Millwork, and Wood Panel Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Willis site logged 3 recordable injuries or illnesses among about 107 workers: 3.1 per 100 full-time workers, against a median of 4.6 for its industry. Those cases cost 2 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
JFM International
Willis · 2025
107 313.14.6
JFM International Inc.
Willis · 2023
89 505.14.2
JFM International - Plant 3
Willis · 2023
25 217.14.6

Included with any plan: 5 more yearly logs from these sites, back to 2020, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 4 reports on file.

Apr 19, 2024, Willis: Amputation · amputations involving bone loss · other finger(s) n.e.c.

An employee was adjusting a chain on a machine. The machine started, and its chain and sprocket caused a partial amputation to the last joint on his right middle finger.

Jun 14, 2023, Willis: Amputation · amputations · fingertip(s)

An employee was cutting a piece of wood with a table saw when her right thumb tip was amputated.

Oct 9, 2020, Willis: Hospitalization, amputation · amputations · finger(s), fingernail(s), n.e.c.

An employee was clearing debris in a wood grinding machine and amputated her right little finger.

Oct 1, 2018, Willis: Hospitalization · fractures · hip(s)

An employee was feeding a planer when his heel caught on the table leg. He fell to the ground, breaking his hip; he was hospitalized.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.29 · Injury and illness log

29 CFR 1904.29(b)(3)

(3) How quickly must each injury or illness be recorded? You must enter each recordable injury or illness on the OSHA 300 Log and 301 Incident Report within seven (7) calendar days of receiving information that a recordable injury or illness has occurred.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.95 · Noise

Other lumber, plywood, millwork, and wood panel merchant wholesalers employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.