OSHA SearchOSHA records by employer

JG Lara Paint LLC: OSHA inspections and violations

Winston Salem, North Carolina · Painting and Wall Covering Contractors · NAICS 238320

1inspections
6citation items
$1,600current penalties
Mar 11, 2019last inspection

OSHA has inspected JG Lara Paint LLC once in North Carolina.

The inspection began on Mar 11, 2019, in Winston Salem.

That inspection ended with 6 citation items: 6 serious.

Penalties were first proposed at $1,600 and still stand at $1,600.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and JG Lara Paint LLC averages $1,600 (1 cited inspection).

JG Lara Paint LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch JG Lara Paint LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343850657 OPENED MAR 11, 2019Closed

Unprogrammed other · Complete · Safety · 6 employees at the site · Closed Feb 7, 2025

270 Meadowlark Drive, Winston Salem, NC 27104 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.300(a) · Tools—Hand and Power: general requirements
Serious$600$600May 16, 2019Final
Citation 1, item 1b
29 CFR 1926.300(c) · Tools—Hand and Power: general requirements
Serious$0$0May 16, 2019Final
Citation 1, item 2a
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$1,000$1,000May 16, 2019Final
Citation 1, item 2b
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$0$0May 16, 2019Final
Citation 1, item 2c
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0May 16, 2019Final
Citation 1, item 2d
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0May 16, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(a)

(a) Condition of tools. All hand and power tools and similar equipment, whether furnished by the employer or the employee, shall be maintained in a safe condition.

29 CFR 1926.300(c)

(c) Personal protective equipment. Employees using hand and power tools and exposed to the hazard of falling, flying, abrasive, and splashing objects, or exposed to harmful dusts, fumes, mists, vapors, or gases shall be provided with the particular personal protective equipment necessary to protect them from the hazard. All personal protective equipment shall meet the requirements and be maintained according to subparts D and E of this part.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

Other painting and wall covering contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.