Inspection 348645078 OPENED DEC 16, 2025Closed
133-25 37th Avenue, Flushing, NY 11354 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
White Plains, New York · All Other Specialty Trade Contractors · NAICS 238990
JGR Services Inc. has 2 OSHA inspections on record in New York, the first in 2022.
OSHA's last visit started on Dec 16, 2025 as part of a related case, in Flushing.
Across those inspections OSHA issued 4 citation items: 4 serious.
OSHA proposed $14,089 in penalties. After settlements and reviews the total is $9,500, down 33%.
Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. JGR Services Inc. averages $9,500 over 1 cited inspection in that time.
New York · latest 90 days of OSHA records
359employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch JGR Services Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company133-25 37th Avenue, Flushing, NY 11354 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
131 Mamaroneck Ave., White Plains, NY 10601 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements |
Serious | $4,144 | $2,793 | Jun 9, 2022 | Final |
| Citation 1, item 2 29 CFR 1926.451(c)(2) · Scaffolds, general requirements |
Serious | $4,144 | $2,793 | Jun 9, 2022 | Final |
| Citation 1, item 3a 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $5,801 | $3,914 | Jun 9, 2022 | Final |
| Citation 1, item 3b 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $0 | $0 | Jun 9, 2022 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(c)(1)(ii)
(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).
29 CFR 1926.451(c)(2)
(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.