OSHA SearchOSHA records by employer

Jimenez Construction LLC: OSHA inspections and violations

Bend, Oregon · Finish Carpentry Contractors · NAICS 238350

5inspections
10citation items
$820current penalties
Aug 7, 2017last inspection

Since 2010, OSHA inspectors have visited Jimenez Construction LLC in Oregon 5 times.

The most recent inspection opened on Aug 7, 2017 as a planned inspection, in Scappoose and is still open.

In all, OSHA issued 10 citation items: 4 serious, 1 repeat and 5 other-than-serious.

The penalties, $820 in total, stand where OSHA first set them.

The rule cited most here is 1926.404 (ground-fault protection on job sites), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Jimenez Construction LLC averages $250 across 2 cited inspections.

Jimenez Construction LLC: OSHA citation items per year, 2010 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Jimenez Construction LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342527850 OPENED AUG 7, 2017Open

Planned · Complete · Safety · 2 employees at the site · Open

50611 Hemlock Ave, Scappoose, OR 97056 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-001-0765(13)-1
Repeat$200$200Nov 1, 2017Open

Inspection 341125235 OPENED DEC 2, 2015Open

Planned · Partial · Safety · 14 employees at the site · Open

215 Oswego Summit, Lake Oswego, OR 97035 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR OAR 437-001-0765(13)-1
Serious$200$200Feb 11, 2016Open
Citation 2, item 3
29 CFR OAR 437-001-0700(22)
Other-than-serious$100$100Feb 11, 2016Open

Inspection 316640994 OPENED JUL 18, 2013Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jan 6, 2014

216 Sw Division St, Sublimity, OR 97385 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Aug 21, 2013Closed
Citation 1, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Aug 21, 2013Closed

Inspection 316712181 OPENED NOV 16, 2012Closed

Complaint · Partial · Safety · 14 employees at the site · Closed Jun 18, 2013

2088 Nw Cadbury Ave, Hillsboro, OR 97006 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(3)(i) · Scaffolds, general requirements
Serious$120$120Dec 17, 2012Closed

Inspection 313464703 OPENED MAR 22, 2010Closed

Planned · Complete · Safety · 8 employees at the site · Closed Aug 22, 2012

20811 Tamar Ln, Bend, OR 97702 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(a)(2) · Ground-fault protection on job sites
Serious$100$100Apr 9, 2010Closed
Citation 1, item 2
29 CFR 1926.50(d)(1) · Medical services and first aid
Serious$100$100Apr 9, 2010Closed
Citation 2, item 3
29 CFR 1926.150(c)(1)(i) · Fire protection
Other-than-serious$0$0Apr 9, 2010Closed
Citation 2, item 4
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Apr 9, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(a)(2)

(2) Polarity of connections. No grounded conductor shall be attached to any terminal or lead so as to reverse designated polarity.

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.50 · Medical services and first aid

29 CFR 7030.4040

Other finish carpentry contractors employers in Oregon

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.