Jimerico Construction, Inc.: OSHA inspections and violations

Schenectady, New York · Other Building Finishing Contractors · NAICS 238390

1inspections
2citation items
$1,665current penalties
Feb 8, 2016last inspection

OSHA has inspected Jimerico Construction, Inc. once in New York.

The inspection began on Feb 8, 2016 after a complaint, in Schenectady.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $2,220 and now stand at $1,665, 25% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Jimerico Construction, Inc. averages $1,665 (1 cited inspection).

Jimerico Construction, Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

356employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Jimerico Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341235992 OPENED FEB 8, 2016Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Jun 21, 2016

93 W. Campbell Road, Schenectady, NY 12306 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(i)(1)(i) · Electrical equipment on job sites
Serious$1,200$900Mar 4, 2016Final
Citation 1, item 2
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$1,020$765Mar 4, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(i)(1)(i)

(i) Working clearances. Except as required or permitted elsewhere in this subpart, the dimension of the working space in the direction of access to live parts operating at 600 volts or less and likely to require examination, adjustment, servicing, or maintenance while alive shall not be less than indicated in Table K-1. In addition to the dimensions shown in Table K-1, workspace shall not be less than 30 inches (762 mm) wide in front of the electric equipment. Distances shall be measured from the live parts if they are exposed, or from the enclosure front or opening if the live parts are enclosed. Walls constructed of concrete, brick, or tile are considered to be grounded. Working space is not required in back of assemblies such as dead-front switchboards or motor control centers where there are no renewable or adjustable parts such as fuses or switches on the back and where all connecti

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(4)(ii)

(ii) Each employee on a walking/working surface shall be protected from tripping in or stepping into or through holes (including skylights) by covers.