OSHA SearchOSHA records by employer

JJ Concrete Walls, LLC: OSHA inspections and violations

Sandy Springs, Georgia · Poured Concrete Foundation and Structure Contractors · NAICS 238110

1inspections
1citation items
$1,955current penalties
Jun 26, 2017last inspection

OSHA has inspected JJ Concrete Walls, LLC once in Georgia.

The inspection began on Jun 26, 2017 on a referral, in Sandy Springs.

That inspection ended with 1 citation item: 1 serious.

Penalties were first proposed at $3,259 and now stand at $1,955, 40% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and JJ Concrete Walls, LLC averages $1,955 (1 cited inspection).

JJ Concrete Walls, LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

150employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch JJ Concrete Walls, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342434628 OPENED JUN 26, 2017Closed

Referral · Partial · Safety · 10 employees at the site · Closed Oct 4, 2017

5755 Glenridge Drive, Sandy Springs, GA 30328 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.703(a)(1) · Requirements for cast-in-place concrete
Serious$3,259$1,955Sep 18, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.703 · Requirements for cast-in-place concrete

29 CFR 1926.703(a)(1)

(a) General requirements for formwork. (1) Formwork shall be designed, fabricated, erected, supported, braced and maintained so that it will be capable of supporting without failure all vertical and lateral loads that may reasonably be anticipated to be applied to the formwork. Formwork which is designed, fabricated, erected, supported, braced and maintained in conformance with the appendix to this section will be deemed to meet the requirements of this paragraph.

Other poured concrete foundation and structure contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.