OSHA SearchOSHA records by employer

JLK Constructors Company, Inc.: OSHA inspections and violations

Fort Lauderdale, Florida · Other Building Finishing Contractors · NAICS 238390

1inspections
3citation items
$5,750current penalties
Jun 30, 2017last inspection

OSHA has inspected JLK Constructors Company, Inc. once in Florida.

The inspection began on Jun 30, 2017 as a planned inspection, in Fort Lauderdale.

That inspection ended with 3 citation items: 2 serious and 1 other-than-serious.

Penalties were first proposed at $9,584 and now stand at $5,750, 40% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and JLK Constructors Company, Inc. averages $5,750 (1 cited inspection).

JLK Constructors Company, Inc.: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch JLK Constructors Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342446671 OPENED JUN 30, 2017Closed

Planned · Partial · Safety · 71 employees at the site · Closed Feb 7, 2018

600 E. Las Olas Blvd., Fort Lauderdale, FL 33301 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1)(ii) · Scaffolds, general requirements
Serious$8,873$5,324Nov 9, 2017Final
Citation 1, item 1b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Nov 9, 2017Final
Citation 2, item 1
29 CFR 1926.502(d)(20) · Fall protection systems
Other-than-serious$711$427Nov 9, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(1)(ii)

(ii) Each employee on a single-point or two-point adjustable suspension scaffold shall be protected by both a personal fall arrest system and guardrail system;

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(d)(20)

(20) The employer shall provide for prompt rescue of employees in the event of a fall or shall assure that employees are able to rescue themselves.