OSHA SearchOSHA records by employer

JM Welding Inc.: OSHA inspections and violations

Chester, Pennsylvania · Ornamental and Architectural Metal Work Manufacturing · NAICS 332323

1inspections
9citation items
$6,928current penalties
May 17, 2017last inspection

OSHA has inspected JM Welding Inc. once in Pennsylvania.

The inspection began on May 17, 2017 as a planned inspection, in Chester.

That inspection ended with 9 citation items: 7 serious and 2 other-than-serious.

Penalties were first proposed at $9,237 and now stand at $6,928, 25% lower after settlements or reviews.

Overhead and gantry cranes comes up most often in these citations: 3 items under 1910.179.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and JM Welding Inc. averages $6,928 (1 cited inspection).

JM Welding Inc.: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch JM Welding Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342340494 OPENED MAY 17, 2017Closed

Planned · Complete · Health · 10 employees at the site · Closed Feb 8, 2018

916 Lamokin Street, Chester, PA 19013 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.36(d)(1) · Exit route design
Serious$2,173$1,630Nov 8, 2017Final
Citation 1, item 1b
29 CFR 1910.37(a)(3) · Exit routes
Serious$0$0Nov 8, 2017Final
Citation 1, item 2a
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Serious$1,630$1,222Nov 8, 2017Final
Citation 1, item 2b
29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes
Serious$0$0Nov 8, 2017Final
Citation 1, item 2c
29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes
Serious$0$0Nov 8, 2017Final
Citation 1, item 3
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$2,717$2,038Nov 8, 2017Final
Citation 1, item 4
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$2,717$2,038Nov 8, 2017Final
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Nov 8, 2017Final
Citation 2, item 2
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$0$0Nov 8, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1910.134(c)(2)(ii)

(ii) In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks).

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.179(j)(2)(iii)

(iii) Hooks with deformation or cracks. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected. For hooks with cracks or having more than 15 percent in excess of normal throat opening or more than 10° twist from the plane of the unbent hook refer to paragraph (l)(3)(iii)(a) of this section.

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

Other ornamental and architectural metal work manufacturing employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.