OSHA SearchOSHA records by employer

Jmcexcavation Inc.: OSHA inspections and violations

Park City, Utah · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

1inspections
3citation items
$1,365current penalties
Oct 1, 2024last inspection

OSHA inspectors have visited Jmcexcavation Inc. in Utah one time.

It opened on Oct 1, 2024 after a complaint, in Park City.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $2,730; today they stand at $1,365, 50% less.

The rule cited most here is 1926.651 (excavations), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Jmcexcavation Inc. averages $1,365 across 1 cited inspection.

Jmcexcavation Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

70employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Jmcexcavation Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347787095 OPENED OCT 1, 2024Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Jan 14, 2025

9330 Marsac Avenue, Park City, UT 84060 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.651(f) · Excavations
Serious$2,100$1,050Nov 8, 2024Final
Citation 1, item 1b
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Nov 8, 2024Final
Citation 1, item 2
29 CFR 1926.652(b) · Trench protection
Serious$630$315Nov 8, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(f)

(f) Warning system for mobile equipment. When mobile equipment is operated adjacent to an excavation, or when such equipment is required to approach the edge of an excavation, and the operator does not have a clear and direct view of the edge of the excavation, a warning system shall be utilized such as barricades, hand or mechanical signals, or stop logs. If possible, the grade should be away from the excavation.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(b)

(b) Design of sloping and benching systems. The slopes and configurations of sloping and benching systems shall be selected and constructed by the employer or his designee and shall be in accordance with the requirements of paragraph (b)(1); or, in the alternative, paragraph (b)(2); or, in the alternative, paragraph (b)(3), or, in the alternative, paragraph (b)(4), as follows:

Other new multifamily housing construction (except for-sale builders) employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.