OSHA SearchOSHA records by employer

JMMS Stucco and Construction, LLC: OSHA inspections and violations

Akron, Ohio · Siding Contractors · NAICS 238170

1inspections
5citation items
$7,970current penalties
Apr 18, 2023last inspection

OSHA inspectors have visited JMMS Stucco and Construction, LLC in Ohio one time.

It opened on Apr 18, 2023 as a planned inspection, in Akron and is still open.

In all, OSHA issued 5 citation items: 5 serious.

The proposed penalties came to $22,770; today they stand at $7,970, 65% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. JMMS Stucco and Construction, LLC averages $7,970 across 1 cited inspection.

JMMS Stucco and Construction, LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

257employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch JMMS Stucco and Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346647621 OPENED APR 18, 2023Open

Planned · Partial · Safety · 5 employees at the site · Open

2708 S. Main St, Akron, OH 44319 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$4,018$1,594Jun 16, 2023Final
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$4,688$1,594Jun 16, 2023Final
Citation 1, item 3
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$4,688$1,594Jun 16, 2023Final
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,688$1,594Jun 16, 2023Final
Citation 1, item 5
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$4,688$1,594Jun 16, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

Other siding contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.