OSHA SearchOSHA records by employer

JMP Construction: OSHA inspections and violations

Centennial, Colorado · Roofing Contractors · NAICS 238160

2inspections
3citation items
$3,120current penalties
Nov 3, 2015last inspection

JMP Construction has 2 OSHA inspections on record in Colorado, the first in 2015.

OSHA's last visit started on Nov 3, 2015 after a complaint, in Aurora.

Across those inspections OSHA issued 3 citation items: 3 serious.

OSHA proposed $5,600 in penalties. After settlements and reviews the total is $3,120, down 44%.

Most often, OSHA cited 1926.501, fall protection in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,078. JMP Construction averages $1,560 over 2 cited inspections in that time.

JMP Construction: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites JMP Construction again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341034635 OPENED NOV 3, 2015Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Sep 9, 2016

19965 E. Vassar Ave, Aurora, CO 80013 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$1,200$720Nov 13, 2015Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,000$1,200Nov 13, 2015Final

Inspection 340464726 OPENED MAR 12, 2015Closed

Planned · Partial · Safety · 3 employees at the site · Closed Sep 30, 2015

5678 S Himalaya, Centennial, CO 80111 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,400$1,200Mar 25, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.