Joe Swartz Electric Co., Ltd: OSHA inspections and violations
Lewisville, Texas · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210
3inspections
5citation items
$6,018current penalties
Jan 13, 2016last inspection
OSHA has inspected Joe Swartz Electric Co., Ltd 3 times in Texas since 1986.
The latest one began on Jan 13, 2016, in Sugar Land.
Those inspections ended with 5 citation items: 3 serious and 2 other-than-serious.
Penalties were first proposed at $6,970 and now stand at $6,018, 14% lower after settlements or reviews.
Job-site wiring comes up most often in these citations: 2 items under 1926.405.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Joe Swartz Electric Co., Ltd averages $4,500 (1 cited inspection).
Joe Swartz Electric Co., Ltd also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Texas · latest 90 days of OSHA records
399employers cited
10 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Joe Swartz Electric Co., Ltd and get notified the morning OSHA posts a new citation for it.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Houston site logged 3 recordable injuries or illnesses among about 51 workers: 5.3 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 81 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Electric
Houston · 2024
51
3
3
5.3
1.8
Joe Swartz Electric Co., LTD
Houston · 2023
71
7
1
9.8
1.8
Joe Swartz Electric
Houston · 2022
97
12
3
10.4
1.8
Included with any plan: 1 more yearly log from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.
(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.
29 CFR 1926.405(d)
(d) Switchboards and panelboards. Switchboards that have any exposed live parts shall be located in permanently dry locations and accessible only to qualified persons. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. Exposed blades of knife switches shall be dead when open.
Other electrical contractors and other wiring installation contractors employers in Texas
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.