OSHA SearchOSHA records by employer

Joey Construction, LLC: OSHA inspections and violations

Acworth, Georgia · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

2inspections
3citation items
$10,988current penalties
Jun 11, 2020last inspection

Since 2013, OSHA inspectors have visited Joey Construction, LLC in Georgia 2 times.

The most recent inspection opened on Jun 11, 2020 as a planned inspection, in Atlanta.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $10,988 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Joey Construction, LLC averages $10,988 across 1 cited inspection.

Joey Construction, LLC: OSHA citation items per year, 2013 to 2020
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

146employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Joey Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344786637 OPENED JUN 11, 2020Closed

Planned · Partial · Safety · 6 employees at the site · Closed Feb 21, 2023

(lot #152) Albany Way, Atlanta, GA 30347 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(d) · Woodworking tools
Serious$2,892$2,892Jul 15, 2020Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,048$4,048Jul 15, 2020Final
Citation 1, item 3
29 CFR 1926.502(d)(6)(i) · Fall protection systems
Serious$4,048$4,048Jul 15, 2020Final

Inspection 339020299 OPENED MAR 12, 2013Closed

Planned · Complete · Safety · 4 employees at the site · Closed Aug 19, 2013

208 Fairway Drive, Acworth, GA 30101 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(d)

(d) Guarding. All portable, power-driven circular saws shall be equipped with guards above and below the base plate or shoe. The upper guard shall cover the saw to the depth of the teeth, except for the minimum arc required to permit the base to be tilted for bevel cuts. The lower guard shall cover the saw to the depth of the teeth, except for the minimum arc required to allow proper retraction and contact with the work. When the tool is withdrawn from the work, the lower guard shall automatically and instantly return to the covering position.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(d)(6)(i)

(i) directly to webbing, rope or wire rope;

Other new single-family housing construction (except for-sale builders) employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.