OSHA SearchOSHA records by employer

John Day: OSHA inspections and violations

Hatton, Kentucky · Commercial and Institutional Building Construction · NAICS 236220

1inspections
4citation items
$1,750current penalties
Mar 5, 2018last inspection

OSHA has inspected John Day once in Kentucky.

The inspection began on Mar 5, 2018 on a referral, in Hatton; the case is still open.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $1,750 and still stand at $1,750.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and John Day averages $1,750 (1 cited inspection).

John Day: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites John Day again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343001327 OPENED MAR 5, 2018Open

Referral · Partial · Safety · 4 employees at the site · Open

1169 Us 127 South, Hatton, KY 40601 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,750$1,750Jul 26, 2018Final
Citation 1, item 1b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Jul 26, 2018Final
Citation 1, item 1c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Jul 26, 2018Final
Citation 1, item 1d
29 CFR 1926.451(g)(1)(iv) · Scaffolds, general requirements
Serious$0$0Jul 26, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

Other commercial and institutional building construction employers in Kentucky