Inspection 347346611 OPENED MAR 13, 2024Closed
400 E Martin Street, Raleigh, NC 27601 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Raleigh, North Carolina · Residential Remodelers · NAICS 236118
Since 2016, OSHA inspectors have visited John R McCoy Construction LLC in North Carolina 2 times.
The most recent inspection opened on Mar 13, 2024 as part of a related case, in Raleigh.
In all, OSHA issued 4 citation items: 1 serious and 3 other-than-serious.
The penalties, $300 in total, stand where OSHA first set them.
The rule cited most here is 1910.134 (respiratory protection), 3 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. John R McCoy Construction LLC averages $300 across 1 cited inspection.
North Carolina · latest 90 days of OSHA records
234employers cited
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch John R McCoy Construction LLC and get notified the morning OSHA posts a new citation for it.
Watch this company400 E Martin Street, Raleigh, NC 27601 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
600 N Boundary Street, Raleigh, NC 27604 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $300 | $300 | Apr 13, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.134(c)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Apr 13, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.134(f)(2) · Respiratory protection |
Other-than-serious | $0 | $0 | Apr 13, 2016 | Final |
| Citation 2, item 3 29 CFR 1926.1101(f)(1)(i) · Asbestos in construction |
Other-than-serious | $0 | $0 | Apr 13, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.134(c)(1)
(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.
29 CFR 1910.134(e)(1)
(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.
29 CFR 1910.134(f)(2)
(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply, taking caution so as not to hyperventilate.
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.