OSHA SearchOSHA records by employer

Johnson Controls Warranty Reduction Center: OSHA inspections and violations

Columbus, Georgia · Storage Battery Manufacturing · NAICS 335911

2inspections
3citation items
$13,362current penalties
Aug 1, 2017last inspection

OSHA has inspected Johnson Controls Warranty Reduction Center 2 times in Georgia since 2016.

The latest one began on Aug 1, 2017 to follow up on an earlier case, in Columbus.

Those inspections ended with 3 citation items: 2 serious and 1 other-than-serious.

Penalties were first proposed at $22,270 and now stand at $13,362, 40% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Johnson Controls Warranty Reduction Center averages $6,681 (2 cited inspections).

Johnson Controls Warranty Reduction Center: OSHA citation items per year, 2016 to 2017
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

148employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Johnson Controls Warranty Reduction Center and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342576915 OPENED AUG 1, 2017Closed

Follow-up · Partial · Safety · 7 employees at the site · Closed Jan 3, 2018

4825 Cargo Drive, Columbus, GA 31907 · Storage Battery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Dec 6, 2017Final

Inspection 341428779 OPENED APR 26, 2016Closed

Complaint · Partial · Health · 21 employees at the site · Closed Jan 12, 2017

4825 Cargo Drive, Columbus, GA 31907 · Storage Battery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Serious$9,799$5,879Oct 12, 2016Final
Citation 1, item 3
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$12,471$7,483Oct 12, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.151(c)

(c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.334(a)(2)(ii)

(ii) If there is a defect or evidence of damage that might expose an employee to injury, the defective or damaged item shall be removed from service, and no employee may use it until repairs and tests necessary to render the equipment safe have been made.