OSHA SearchOSHA records by employer

Jorge Martinez: OSHA inspections and violations

Lubbock, Texas · Framing Contractors · NAICS 238130

8inspections
23citation items
$57,953current penalties
Aug 27, 2024last inspection

OSHA has inspected Jorge Martinez 8 times in Texas since 2004.

The latest one began on Aug 27, 2024 to follow up on an earlier case, in San Antonio.

Those inspections ended with 23 citation items: 23 serious.

Penalties were first proposed at $59,717 and now stand at $57,953, 3% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 9 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Jorge Martinez averages $11,483 (5 cited inspections).

Jorge Martinez: OSHA citation items per year, 2004 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites Jorge Martinez again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347713307 OPENED AUG 27, 2024Closed

Follow-up · Partial · Safety · 13 employees at the site · Closed Aug 28, 2024

Saint Tropez Place / Rhone River Dr, San Antonio, TX 78255 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347434821 OPENED APR 24, 2024Open

Planned · Partial · Safety · 13 employees at the site · Open

Saint Tropez Place / Rhone River Dr, San Antonio, TX 78255 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.100(a) · Hard hats in construction
Serious$3,687$3,687Jun 3, 2024Final
Citation 1, item 1b
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$0$0Jun 3, 2024Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,687$3,687Jun 3, 2024Final
Citation 1, item 3
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$3,687$3,687Jun 3, 2024Final
Citation 1, item 4
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$3,687$3,687Jun 3, 2024Final

Inspection 346677495 OPENED MAY 3, 2023Closed

Planned · Partial · Safety · 7 employees at the site · Closed Oct 21, 2024

Vicinity Of Fm 6 And Cr2606 East Of Cr 2606 Approx. 5200 Block Of Fm6, Josephine, TX 75135 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$3,349$3,349Aug 25, 2023Final
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$4,688$4,688Aug 25, 2023Final
Citation 1, item 3
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$4,688$4,688Aug 25, 2023Final
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,688$4,688Aug 25, 2023Final
Citation 1, item 5a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,688$4,688Aug 25, 2023Final
Citation 1, item 5b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Aug 25, 2023Final
Citation 1, item 6
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$4,688$4,688Aug 25, 2023Final
Citation 1, item 7
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$4,688$4,688Aug 25, 2023Final

Inspection 345703334 OPENED DEC 27, 2021Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 23, 2026

8141 Beach Break, Port Aransas, TX 78373 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$3,170$3,170Jan 21, 2022Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Jan 21, 2022Final

Inspection 345484489 OPENED AUG 17, 2021Closed

Planned · Partial · Safety · 6 employees at the site · Closed Aug 23, 2024

2715 Viola Ave, Lubbock, TX 79424 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,755$1,053Sep 9, 2021Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,755$1,053Sep 9, 2021Final

Inspection 343259016 OPENED JUN 27, 2018Closed

Planned · Partial · Safety · 11 employees at the site · Closed Feb 17, 2023

6415 62nd St., Lubbock, TX 79424 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,956$2,956Aug 24, 2018Final
Citation 1, item 2a
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$2,956$2,956Aug 24, 2018Final
Citation 1, item 2b
29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements
Serious$0$0Aug 24, 2018Final

Inspection 312538432 OPENED SEP 22, 2008Closed

Planned · Partial · Safety · 3 employees at the site · Closed Oct 30, 2008

8001 S. Padre Island Dr., Corpus Christi, TX 78412 · Flooring Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$450$270Sep 30, 2008Closed
Citation 1, item 1b
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$0$0Sep 30, 2008Closed
Citation 1, item 2
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$450$270Sep 30, 2008Closed

Inspection 306206541 OPENED MAY 7, 2004Closed

Unprogrammed other · Complete · Safety · 10 employees at the site · Closed Sep 30, 2004

Highway 377 North Bound, Keller, TX 76248 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.95 · Criteria for personal protective equipment

Other framing contractors employers in Texas