OSHA SearchOSHA records by employer

Jorge Moreno: OSHA inspections and violations

Dallas, Texas · Masonry Contractors · NAICS 238140

2inspections
6citation items
$28,671current penalties
Jul 14, 2021last inspection

Since 2017, OSHA inspectors have visited Jorge Moreno in Texas 2 times.

The most recent inspection opened on Jul 14, 2021 as a planned inspection, in Princeton and is still open.

In all, OSHA issued 6 citation items: 5 serious and 1 repeat.

The proposed penalties came to $33,231; today they stand at $28,671, 14% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Jorge Moreno averages $14,336 across 2 cited inspections.

Jorge Moreno: OSHA citation items per year, 2017 to 2021
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Jorge Moreno and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345417885 OPENED JUL 14, 2021Open

Planned · Partial · Safety · 5 employees at the site · Open

200 Cole St. Bldg.: 8, Princeton, TX 75407 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$4,505$4,505Aug 23, 2021Final
Citation 1, item 2
29 CFR 1926.451(b)(3) · Scaffolds, general requirements
Serious$4,505$4,505Aug 23, 2021Final
Citation 2, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$9,011$9,011Aug 23, 2021Final

Inspection 342625654 OPENED SEP 6, 2017Closed

Fatality or catastrophe · Partial · Safety · 15 employees at the site · Closed Feb 12, 2019

4005 Gaston Ave., Dallas, TX 75246 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Sep 5, 2017: Three workers fall when scaffold collapses and are hosptiali

At 3:00 p.m. on September 5, 2017, Employees #1, #2, and #3, employed by a construction company, were working at a multiemployer building construction project. They were working from a scaffold when the scaffold collapsed. The three employees fell. Emergency services were called, and the three employees were transported to the hospital, admitted, and treated for their injuries. The subsequent investigation determined that the scaffold was not properly secured to the building.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$5,070$3,550Dec 21, 2017Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$5,070$3,550Dec 21, 2017Final
Citation 1, item 3
29 CFR 1926.451(f)(12) · Scaffolds, general requirements
Serious$5,070$3,550Dec 21, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(b)(3)

(3) Except as provided in paragraphs (b)(3) (i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling.

29 CFR 1926.451(c)(1)