OSHA SearchOSHA records by employer

Jorge Pena Stucco: OSHA inspections and violations

Tampa, Florida · Masonry Contractors · NAICS 238140

1inspections
3citation items
$11,640current penalties
Feb 23, 2018last inspection

OSHA inspectors have visited Jorge Pena Stucco in Florida one time.

It opened on Feb 23, 2018 on a referral, in Tampa.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $11,640 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Jorge Pena Stucco averages $11,640 across 1 cited inspection.

Jorge Pena Stucco: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Jorge Pena Stucco and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342972718 OPENED FEB 23, 2018Closed

Referral · Partial · Safety · 5 employees at the site · Closed Apr 18, 2023

5010 Cortez Ave., Tampa, FL 33614 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$3,880$3,880May 22, 2018Final
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$3,880$3,880May 22, 2018Final
Citation 1, item 3
29 CFR 1926.454(b) · Scaffold training
Serious$3,880$3,880May 22, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.454(b)

(b) The employer shall have each employee who is involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question. The training shall include the following topics, as applicable:

Other masonry contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.