OSHA SearchOSHA records by employer

Jornik Manufacturing Corp.: OSHA inspections and violations

Stamford, Connecticut · Commercial Screen Printing · NAICS 323113

4inspections
33citation items
$12,100current penalties
Oct 20, 2016last inspection

Since 1997, OSHA inspectors have visited Jornik Manufacturing Corp. in Connecticut 4 times.

The most recent inspection opened on Oct 20, 2016 after a complaint, in Stamford.

In all, OSHA issued 33 citation items: 18 serious and 15 other-than-serious.

The proposed penalties came to $28,392; today they stand at $12,100, 57% less.

The rule cited most here is 1910.1200 (hazard communication), 12 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Jornik Manufacturing Corp. averages $10,600 across 1 cited inspection.

Jornik Manufacturing Corp. also files yearly injury logs with OSHA, summarized below.

Jornik Manufacturing Corp.: OSHA citation items per year, 1997 to 2016
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

88employers cited

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch Jornik Manufacturing Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341863942 OPENED OCT 20, 2016Closed

Complaint · Partial · Safety · 40 employees at the site · Closed Dec 13, 2019

652 Glenbrook Road Bldg 8-2, Stamford, CT 06906 · Commercial Printing (except Screen and Books) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.37(a)(2) · Exit routes
Serious$6,236$3,118Jan 11, 2017Final
Citation 1, item 1b
29 CFR 1910.106(d)(3)(ii) · Flammable liquids
Serious$0$0Jan 11, 2017Final
Citation 1, item 2a
29 CFR 1910.133(a)(1) · Eye and face protection
Other-than-serious$3,741$0Jan 11, 2017Final
Citation 1, item 2b
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Jan 11, 2017Final
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$4,988$2,494Jan 11, 2017Final
Citation 1, item 4a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$6,236$3,118Jan 11, 2017Final
Citation 1, item 4b
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$0$0Jan 11, 2017Final
Citation 1, item 4c
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Jan 11, 2017Final
Citation 1, item 5a
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Serious$3,741$1,870Jan 11, 2017Final
Citation 1, item 5b
29 CFR 1910.1200(f)(6) · Hazard communication
Serious$0$0Jan 11, 2017Final
Citation 1, item 5c
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Jan 11, 2017Final

Inspection 308297944 OPENED MAR 11, 2005Closed

Complaint · Partial · Health · 17 employees at the site · Closed May 18, 2006

652 Glenbrook Road, Bldg. #8, Stamford, CT 06906 · Commercial Screen Printing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1b
29 CFR 1910.106(e)(9)(iii) · Flammable liquids
Other-than-serious$0$0Aug 24, 2005Closed
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Serious$600$300Aug 24, 2005Closed
Citation 1, item 3
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$600$300Aug 24, 2005Closed
Citation 1, item 4a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$450$225Aug 24, 2005Closed
Citation 1, item 4b
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$0$0Aug 24, 2005Closed
Citation 1, item 5
29 CFR 1910.1200(h) · Hazard communication
Serious$450$225Aug 24, 2005Closed
Citation 1, item 6a
29 CFR 1910.1200(h)(1)(i) · Hazard communication
Serious$450$225Aug 24, 2005Closed
Citation 1, item 6b
29 CFR 1910.1200(h)(2)(iii) · Hazard communication
Serious$0$0Aug 24, 2005Closed
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Aug 24, 2005Closed

Inspection 301734117 OPENED MAR 23, 1999Closed

Follow-up · Partial · Health · 9 employees at the site · Closed Apr 5, 1999

652 Glenbrook Road, Bldg. #8, Stamford, CT 06906 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 123293383 OPENED APR 9, 1997Closed

Complaint · Partial · Health · 7 employees at the site · Closed Sep 17, 1997

652 Glenbrook Road, Bldg. #8, Stamford, CT 06906 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Serious$450$225May 2, 1997Closed
Citation 1, item 1b
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0May 2, 1997Closed
Citation 1, item 2a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$450$0May 2, 1997Closed
Citation 1, item 2b
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$0$0May 2, 1997Closed
Citation 1, item 2c
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0May 2, 1997Closed
Citation 1, item 2d
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0May 2, 1997Closed
Citation 1, item 2e
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0May 2, 1997Closed
Citation 2, item 1
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0May 2, 1997Closed
Citation 2, item 2
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0May 2, 1997Closed
Citation 2, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0May 2, 1997Closed
Citation 2, item 4
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0May 2, 1997Closed
Citation 2, item 5
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$0$0May 2, 1997Closed
Citation 2, item 6
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0May 4, 1997Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Stamford site logged 2 recordable injuries or illnesses among about 155 workers: 1.9 per 100 full-time workers, against a median of 2.0 for its industry. Those cases cost 3 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
jornik manufacturing Acquisition
Stamford · 2023
155 221.92.0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(3)(ii)

(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”

29 CFR 1910.106(e)(9)(iii)

(iii) Waste and residue. Combustible waste material and residues in a building or unit operating area shall be kept to a minimum, stored in covered metal receptacles and disposed of daily.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes