Jose Becerra Martinez: OSHA inspections and violations

Magnolia, Texas · Masonry Contractors · NAICS 238140

1inspections
3citation items
$5,993current penalties
Feb 5, 2024last inspection

OSHA inspectors have visited Jose Becerra Martinez in Texas one time.

It opened on Feb 5, 2024 as a planned inspection, in Magnolia and is still open.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $13,830; today they stand at $5,993, 57% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Jose Becerra Martinez averages $5,993 across 1 cited inspection.

Jose Becerra Martinez: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

401employers cited

14 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Jose Becerra Martinez and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347257693 OPENED FEB 5, 2024Open

Planned · Partial · Safety · 12 employees at the site · Open

765 Fish Creek Thoroughfare, Magnolia, TX 77353 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,610$2,996Mar 14, 2024Final
Citation 1, item 2a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,610$2,996Mar 14, 2024Final
Citation 1, item 2b
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$4,610$0Mar 14, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(c)(2)

(2) Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.