OSHA SearchOSHA records by employer

Jose David Henrriquez Barrera: OSHA inspections and violations

Parkville, Maryland · Siding Contractors · NAICS 238170

1inspections
5citation items
$1,800current penalties
May 26, 2017last inspection

OSHA inspectors have visited Jose David Henrriquez Barrera in Maryland one time.

It opened on May 26, 2017 as a planned inspection, in Parkville.

In all, OSHA issued 5 citation items: 5 serious.

The penalties, $1,800 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Jose David Henrriquez Barrera averages $1,800 across 1 cited inspection.

Jose David Henrriquez Barrera: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

183employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Jose David Henrriquez Barrera and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342355690 OPENED MAY 26, 2017Closed

Planned · Complete · Safety · 2 employees at the site · Closed Aug 10, 2018

9240 Old Harford Road, Parkville, MD 21234 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$900$900Jul 25, 2017Final
Citation 1, item 1b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Jul 25, 2017Final
Citation 1, item 1c
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Jul 25, 2017Final
Citation 1, item 1d
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Jul 25, 2017Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$900$900Jul 25, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other siding contractors employers in Maryland