OSHA SearchOSHA records by employer

Jose de Olio Pinales: OSHA inspections and violations

Toa Baja, Puerto Rico · Tire Dealers · NAICS 441320

2inspections
6citation items
$10,500current penalties
Mar 26, 2025last inspection

Since 2024, OSHA inspectors have visited Jose de Olio Pinales in Puerto Rico 2 times.

The most recent inspection opened on Mar 26, 2025 to follow up on an earlier case, in Toa Baja.

In all, OSHA issued 6 citation items: 3 serious and 3 other-than-serious.

The penalties, $10,500 in total, stand where OSHA first set them.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 2 times.

Among retail employers, the typical cited inspection since 2015 ends with a $1,750 penalty. Jose de Olio Pinales averages $10,500 across 1 cited inspection.

Jose de Olio Pinales: OSHA citation items per year, 2024 to 2025
Citation items per year, by inspection date.

Puerto Rico · latest 90 days of OSHA records

109employers cited

Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Puerto Rico

Checking a subcontractor, a client or your own company? Watch Jose de Olio Pinales and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348147109 OPENED MAR 26, 2025Closed

Follow-up · Partial · Safety · 4 employees at the site · Closed Jul 14, 2025

Ave. Boulevard, Paseo Durian J-1259, Urb. Levittown, Toa Baja, PR 00951 · Tire Dealers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347625667 OPENED JUL 17, 2024Closed

Referral · Partial · Safety · 2 employees at the site · Closed Apr 21, 2025

Ave. Boulevard, Paseo Durian J-1259, Urb. Levittown, Toa Baja, PR 00951 · Tire Dealers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$2,500$2,500Sep 11, 2024Final
Citation 1, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$2,500$2,500Sep 11, 2024Final
Citation 1, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$2,500$2,500Sep 11, 2024Final
Citation 2, item 1
29 CFR 17 II C 5
Other-than-serious$1,000$1,000Sep 11, 2024Final
Citation 2, item 2
29 CFR 17 IV B 1
Other-than-serious$1,000$1,000Sep 11, 2024Final
Citation 3, item 1
29 CFR 1903 20 B 1
Other-than-serious$1,000$1,000Jan 8, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(1)

(b) Examination, installation, and use of equipment—(1) Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations:

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(2)(iii)

(iii) Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.

Other tire dealers employers in Puerto Rico

Alert subscribers get notified of each newly cited employer in Puerto Rico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.