OSHA SearchOSHA records by employer

Jose Gomez Masonry Inc.: OSHA inspections and violations

Oak Ridge, North Carolina · Masonry Contractors · NAICS 238140

2inspections
18citation items
$7,150current penalties
Feb 17, 2016last inspection

Since 2007, OSHA inspectors have visited Jose Gomez Masonry Inc. in North Carolina 2 times.

The most recent inspection opened on Feb 17, 2016 as a planned inspection, in Lewisville.

In all, OSHA issued 18 citation items: 16 serious and 2 other-than-serious.

The penalties, $7,150 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 11 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Jose Gomez Masonry Inc. averages $5,700 across 1 cited inspection.

Jose Gomez Masonry Inc.: OSHA citation items per year, 2007 to 2016
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

231employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Jose Gomez Masonry Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341260180 OPENED FEB 17, 2016Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jun 9, 2023

5269 Hidden Stream Drive, Lot# 001, Lewisville, NC 27023 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$1,500$1,500Mar 4, 2016Final
Citation 1, item 2
29 CFR 1926.451(e)(6) · Scaffolds, general requirements
Serious$2,100$2,100Mar 4, 2016Final
Citation 1, item 3a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,100$2,100Mar 4, 2016Final
Citation 1, item 3b
29 CFR 1926.451(g)(4)(xv) · Scaffolds, general requirements
Serious$0$0Mar 4, 2016Final

Inspection 310404785 OPENED JUN 5, 2007Closed

Planned · Partial · Safety · 5 employees at the site · Closed Sep 30, 2010

Lot 7, Foxbury, Oak Ridge, NC 27310 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$350$350Jul 6, 2007Closed
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Jul 6, 2007Closed
Citation 1, item 1c
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$0$0Jul 6, 2007Closed
Citation 1, item 2a
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$350$350Jul 6, 2007Closed
Citation 1, item 2b
29 CFR 1926.100(a) · Hard hats in construction
Serious$0$0Jul 6, 2007Closed
Citation 1, item 3a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$250$250Jul 6, 2007Closed
Citation 1, item 3b
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$0$0Jul 6, 2007Closed
Citation 1, item 4a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$250$250Jul 6, 2007Closed
Citation 1, item 4b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Jul 6, 2007Closed
Citation 1, item 4c
29 CFR 1926.454(a)(1) · Scaffold training
Serious$0$0Jul 6, 2007Closed
Citation 1, item 5a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$250$250Jul 6, 2007Closed
Citation 1, item 5b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Jul 6, 2007Closed
Citation 2, item 1
29 CFR 1926.50(d)(1) · Medical services and first aid
Other-than-serious$0$0Jul 6, 2007Closed
Citation 2, item 2
29 CFR 1926.150(c)(1)(i) · Fire protection
Other-than-serious$0$0Jul 6, 2007Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other masonry contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.