OSHA SearchOSHA records by employer

Jose Luis Castro: OSHA inspections and violations

Corpus Christi, Texas · Framing Contractors · NAICS 238130

3inspections
7citation items
$26,441current penalties
Oct 13, 2023last inspection

Since 2011, OSHA inspectors have visited Jose Luis Castro in Texas 3 times.

The most recent inspection opened on Oct 13, 2023 on a referral, in Garland and is still open.

In all, OSHA issued 7 citation items: 7 serious.

The penalties, $26,441 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Jose Luis Castro averages $23,441 across 1 cited inspection.

It reported 1 severe injury to OSHA since 2015.

Jose Luis Castro: OSHA citation items per year, 2011 to 2023
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

56 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Jose Luis Castro and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347032245 OPENED OCT 13, 2023Open

Referral · Partial · Safety · 4 employees at the site · Open

2999 N President George Bush Hwy, Garland, TX 75040 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$4,018$4,018Dec 21, 2023Final
Citation 1, item 2
29 CFR 1926.451(b)(9) · Scaffolds, general requirements
Serious$3,349$3,349Dec 21, 2023Final
Citation 1, item 3
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$4,688$4,688Dec 21, 2023Final
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,688$4,688Dec 21, 2023Final
Citation 1, item 5
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$3,349$3,349Dec 21, 2023Final
Citation 1, item 6
29 CFR 1926.602(d) · Earthmovers and forklifts in construction
Serious$3,349$3,349Dec 21, 2023Final

Inspection 316032184 OPENED NOV 4, 2011Closed

Follow-up · Partial · Safety · 6 employees at the site · Closed Nov 4, 2011

1641 Nile Drive, Corpus Christi, TX 78412 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315785360 OPENED AUG 25, 2011Closed

Planned · Partial · Safety · 6 employees at the site · Closed Dec 17, 2015

1641 Nile Drive, Corpus Christi, TX 78412 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,000$3,000Sep 1, 2011Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Oct 12, 2023, Garland: Hospitalization · fractures · chest, except internal location of diseases or disorders

An employee was on mobile scaffolding installing stucco onto the side of a building when a forklift struck the scaffold, causing it to fall over. The employee fell approximately 15 feet to the concrete driveway below, resulting in four rib fractures. They were hospitalized.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(b)(9)

(9) Wood platforms shall not be covered with opaque finishes, except that platform edges may be covered or marked for identification. Platforms may be coated periodically with wood preservatives, fire-retardant finishes, and slip-resistant finishes; however, the coating may not obscure the top or bottom wood surfaces.

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.602 · Earthmovers and forklifts in construction

Other framing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.