Inspection 344826797 OPENED JUL 8, 2020Closed
3522 Fourth Str., Longview, TX 75605 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Horizon City, Texas · Masonry Contractors · NAICS 238140
Jose Luis Garcia has 4 OSHA inspections on record in Texas, the first in 1993.
OSHA's last visit started on Jul 8, 2020 as a planned inspection, in Longview.
Across those inspections OSHA issued 7 citation items: 6 serious and 1 other-than-serious.
OSHA proposed $23,011 in penalties. After settlements and reviews the total is $14,496, down 37%.
Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Jose Luis Garcia averages $7,248 over 2 cited inspections in that time.
1 inspection on this page followed a fatal incident.
Texas · latest 90 days of OSHA records
401employers cited
14 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Jose Luis Garcia and get notified the morning OSHA posts a new citation for it.
Watch this company3522 Fourth Str., Longview, TX 75605 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
201 Pace Alsbury Ct., Burleson, TX 76028 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $3,741 | $3,741 | Jan 6, 2017 | Final |
| Citation 2, item 1 29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction |
Other-than-serious | $255 | $255 | Jan 6, 2017 | Final |
105 N. 9th Street, Mcallen, TX 78501 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Serious | $3,803 | $2,100 | Mar 10, 2017 | Final |
| Citation 1, item 2 29 CFR 1926.451(c)(2) · Scaffolds, general requirements |
Serious | $3,803 | $2,100 | Mar 10, 2017 | Final |
| Citation 1, item 3 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $3,803 | $2,100 | Mar 10, 2017 | Final |
| Citation 1, item 4 29 CFR 1926.451(f)(6) · Scaffolds, general requirements |
Serious | $3,803 | $2,100 | Mar 10, 2017 | Final |
| Citation 1, item 5 29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements |
Serious | $3,803 | $2,100 | Mar 10, 2017 | Final |
410 Hadley Place, Horizon City, TX 79927 · OSHA's record · Phone and website on Google Maps
Incident on Aug 3, 1993 (fatal): Employee killed in building collapse during storm
At approximately 3:20 p.m. on August 3, 1993, Employee #1 (the employer), and hi s two-man crew were finishing framing the second floor roof on a house under con struction. Without warning a thunderstorm accompanied by high winds of 70 miles per hour or more swooped in from the north and blew the whole house structure up ward and then downward. The second floor collapsed onto the ground, crushing and killing Employee #1 between the ground floor and the wooden substructure.
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(b)(1)
(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:
29 CFR 1926.451(c)(2)
(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.