OSHA SearchOSHA records by employer

Jose Montoya Carpentry LLC: OSHA inspections and violations

Glen Ridge, New Jersey · Siding Contractors · NAICS 238170

1inspections
8citation items
$5,000current penalties
Apr 5, 2017last inspection

OSHA inspectors have visited Jose Montoya Carpentry LLC in New Jersey one time.

It opened on Apr 5, 2017 on a referral, in Glen Ridge.

In all, OSHA issued 8 citation items: 8 serious.

The proposed penalties came to $12,494; today they stand at $5,000, 60% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Jose Montoya Carpentry LLC averages $5,000 across 1 cited inspection.

Jose Montoya Carpentry LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

274employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Jose Montoya Carpentry LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342227972 OPENED APR 5, 2017Closed

Referral · Partial · Health · 4 employees at the site · Closed Aug 30, 2017

58 Harvard St., Glen Ridge, NJ 07028 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(1)(i) · Electrical equipment on job sites
Serious$2,716$1,000Apr 13, 2017Final
Citation 1, item 2a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$2,716$1,000Apr 13, 2017Final
Citation 1, item 2b
29 CFR 1926.404(f)(1)(iv) · Ground-fault protection on job sites
Serious$0$0Apr 13, 2017Final
Citation 1, item 3a
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$2,716$1,000Apr 13, 2017Final
Citation 1, item 3b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Apr 13, 2017Final
Citation 1, item 4a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,716$1,000Apr 13, 2017Final
Citation 1, item 4b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Apr 13, 2017Final
Citation 1, item 5
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$1,630$1,000Apr 13, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)(i)

(i) Suitability for installation and use in conformity with the provisions of this subpart. Suitability of equipment for an identified purpose may be evidenced by listing, labeling, or certification for that identified purpose.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

Other siding contractors employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.