OSHA SearchOSHA records by employer

Jose Reynoso: OSHA inspections and violations

Amarillo, Texas · Masonry Contractors · NAICS 238140

1inspections
5citation items
$8,869current penalties
Jun 25, 2018last inspection

Jose Reynoso has one OSHA inspection on record in Texas.

OSHA opened it on Jun 25, 2018 as a planned inspection, in Amarillo.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $8,869 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Jose Reynoso averages $8,869 over 1 cited inspection in that time.

Jose Reynoso: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Jose Reynoso and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343250833 OPENED JUN 25, 2018Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jul 19, 2022

8403 S New England, Amarillo, TX 79119 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,217$2,217Aug 24, 2018Final
Citation 1, item 1b
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Serious$0$0Aug 24, 2018Final
Citation 1, item 2a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,326$3,326Aug 24, 2018Final
Citation 1, item 2b
29 CFR 1926.451(e)(9)(iv) · Scaffolds, general requirements
Serious$0$0Aug 24, 2018Final
Citation 1, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,326$3,326Aug 24, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(7)

(7) On scaffolds where platforms are overlapped to create a long platform, the overlap shall occur only over supports, and shall not be less than 12 inches (30 cm) unless the platforms are nailed together or otherwise restrained to prevent movement.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.