OSHA SearchOSHA records by employer

Jose Rivera LLC: OSHA inspections and violations

Columbus, Indiana · Flooring Contractors · NAICS 238330

1inspections
5citation items
$600current penalties
Jun 30, 2022last inspection

Jose Rivera LLC has one OSHA inspection on record in Indiana.

OSHA opened it on Jun 30, 2022, in Columbus, and the case has not closed yet.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $600 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.304, woodworking tools (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Jose Rivera LLC averages $600 over 1 cited inspection in that time.

Jose Rivera LLC: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

78employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Jose Rivera LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346053937 OPENED JUN 30, 2022Open

Programmed other · Complete · Safety · 3 employees at the site · Open

3198 Creek Ridge Court, Columbus, IN 47201 · Flooring Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Serious$100$100Jul 15, 2022Final
Citation 1, item 2a
29 CFR 1926.304(f) · Woodworking tools
Serious$300$300Jul 15, 2022Final
Citation 1, item 2b
29 CFR 1926.304(i)(1) · Woodworking tools
Serious$0$0Jul 15, 2022Final
Citation 1, item 3a
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$200$200Jul 15, 2022Final
Citation 1, item 3b
29 CFR 1926.405(d) · Job-site wiring
Serious$0$0Jul 15, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(f)

(f) Other requirements. All woodworking tools and machinery shall meet other applicable requirements of American National Standards Institute, 01.1-1961, Safety Code for Woodworking Machinery.

29 CFR 1926.304(i)(1)

(i) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.405 · Job-site wiring

Other flooring contractors employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.