OSHA SearchOSHA records by employer

JRG Construction, Inc.: OSHA inspections and violations

Souderton, Pennsylvania · Framing Contractors · NAICS 238130

2inspections
12citation items
$14,776current penalties
Dec 27, 2018last inspection

JRG Construction, Inc. has 2 OSHA inspections on record in Pennsylvania, the first in 2018.

OSHA's last visit started on Dec 27, 2018 after a complaint, in Souderton.

Across those inspections OSHA issued 12 citation items: 12 serious.

OSHA proposed $29,552 in penalties. After settlements and reviews the total is $14,776, down 50%.

Most often, OSHA cited 1926.1053, ladders in construction (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. JRG Construction, Inc. averages $7,388 over 2 cited inspections in that time.

JRG Construction, Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

297employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch JRG Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343683876 OPENED DEC 27, 2018Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Mar 11, 2025

Highview At Souderton Lots 3 - 7, Souderton, PA 18964 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$2,842$1,421Mar 28, 2019Final
Citation 1, item 2
29 CFR 1926.28(a) · Personal protective equipment
Serious$3,410$1,705Mar 28, 2019Final
Citation 1, item 3
29 CFR 1926.150(c)(1)(i) · Fire protection
Serious$3,410$1,705Mar 28, 2019Final
Citation 1, item 4a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,978$5,683Mar 28, 2019Final
Citation 1, item 4b
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$3,410$0Mar 28, 2019Final
Citation 1, item 4c
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$0$0Mar 28, 2019Final
Citation 1, item 4d
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,978$0Mar 28, 2019Final
Citation 1, item 4e
29 CFR 1926.1053(b)(5)(i) · Ladders in construction
Serious$0$0Mar 28, 2019Final
Citation 1, item 4f
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Mar 28, 2019Final

Inspection 343517769 OPENED OCT 4, 2018Closed

Planned · Partial · Safety · 3 employees at the site · Closed Oct 22, 2020

13-25 N. School Lane, Souderton, PA 18964 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Serious$2,273$1,136Mar 28, 2019Final
Citation 1, item 2a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,978$3,126Mar 28, 2019Final
Citation 1, item 2b
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$2,273$0Mar 28, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.150 · Fire protection

29 CFR 1926.25 · Housekeeping

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.