OSHA SearchOSHA records by employer

JS Construction, LLC.: OSHA inspections and violations

Landover, Maryland · Siding Contractors · NAICS 238170

4inspections
6citation items
$12,137current penalties
Dec 28, 2021last inspection

Since 2019, OSHA inspectors have visited JS Construction, LLC. in Maryland 4 times.

The most recent inspection opened on Dec 28, 2021 as a planned inspection, in Upper Marlboro and is still open.

In all, OSHA issued 6 citation items: 4 serious and 2 repeat.

The penalties, $12,137 in total, stand where OSHA first set them.

The rule cited most here is 1926.452 (rules for each type of scaffold), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. JS Construction, LLC. averages $3,034 across 4 cited inspections.

JS Construction, LLC.: OSHA citation items per year, 2019 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites JS Construction, LLC. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345705958 OPENED DEC 28, 2021Open

Planned · Complete · Safety · 2 employees at the site · Open

2622 Lewis Street, Upper Marlboro, MD 20774 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,200$1,200Feb 23, 2022Final

Inspection 345595565 OPENED OCT 21, 2021Open

Planned · Complete · Safety · 2 employees at the site · Open

10547, 10549, 10551, 10553 Sally Lane, Lanham, MD 20706 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,400$1,400Dec 8, 2021Final
Citation 2, item 1
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Repeat$5,600$5,600Dec 8, 2021Final

Inspection 344573308 OPENED JAN 17, 2020Open

Referral · Complete · Safety · 5 employees at the site · Open

Lot#: 222-227 Belair Gate Lane, Landover, MD 20785 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Serious$875$875May 28, 2020Final
Citation 2, item 1
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Repeat$2,800$2,800May 28, 2020Final

Inspection 344259155 OPENED AUG 23, 2019Open

Planned · Complete · Safety · 4 employees at the site · Open

827-828 Duvall Ridge Road, Landover, MD 20785 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$262$262Oct 24, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(7)

(7) On scaffolds where platforms are overlapped to create a long platform, the overlap shall occur only over supports, and shall not be less than 12 inches (30 cm) unless the platforms are nailed together or otherwise restrained to prevent movement.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

Other siding contractors employers in Maryland

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.