JSB Masonry, Inc.: OSHA inspections and violations

Whitsett, North Carolina · Masonry Contractors · NAICS 238140

1inspections
3citation items
$0current penalties
Aug 17, 2017last inspection

JSB Masonry, Inc. has one OSHA inspection on record in North Carolina.

OSHA opened it on Aug 17, 2017 as a planned inspection, in Whitsett.

From that inspection OSHA issued 3 citation items: 3 other-than-serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. JSB Masonry, Inc. averages $0 over 1 cited inspection in that time.

JSB Masonry, Inc.: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

237employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch JSB Masonry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342590668 OPENED AUG 17, 2017Closed

Planned · Complete · Safety · 6 employees at the site · Closed Mar 29, 2018

1010 Fairway Village Way, Whitsett, NC 27377 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Other-than-serious$0$0Sep 28, 2017Final
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Other-than-serious$0$0Sep 28, 2017Final
Citation 1, item 3
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Other-than-serious$0$0Sep 28, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.