OSHA SearchOSHA records by employer

JT Hardwood Flooring, LLC: OSHA inspections and violations

Stamford, Connecticut · Flooring Contractors · NAICS 238330

1inspections
1citation items
$1,986current penalties
Nov 25, 2025last inspection

OSHA inspectors have visited JT Hardwood Flooring, LLC in Connecticut one time.

It opened on Nov 25, 2025 on a referral, in Stamford.

In all, OSHA issued 1 citation item: 1 serious.

The proposed penalties came to $3,972; today they stand at $1,986, 50% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. JT Hardwood Flooring, LLC averages $1,986 across 1 cited inspection.

JT Hardwood Flooring, LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

87employers cited

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch JT Hardwood Flooring, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348613241 OPENED NOV 25, 2025Closed

Referral · Partial · Safety · 2 employees at the site · Closed Aug 20, 2026

976 Rock Rimmon Road, Stamford, CT 06903 · Flooring Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(i)(1) · Woodworking tools
Serious$3,972$1,986Jan 23, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(i)(1)

(i) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

Other flooring contractors employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.