OSHA SearchOSHA records by employer

Juan Carlos Montero: OSHA inspections and violations

Austin, Texas · Framing Contractors · NAICS 238130

1inspections
12citation items
$21,028current penalties
May 7, 2019last inspection

OSHA has inspected Juan Carlos Montero once in Texas.

The inspection began on May 7, 2019, in Austin.

That inspection ended with 12 citation items: 12 serious.

Penalties were first proposed at $21,028 and still stand at $21,028.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Juan Carlos Montero averages $21,028 (1 cited inspection).

Juan Carlos Montero: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

56 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Juan Carlos Montero and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343990099 OPENED MAY 7, 2019Closed

Unprogrammed other · Partial · Safety · 10 employees at the site · Closed Oct 4, 2022

7800 East Riverside, Austin, TX 78744 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(iii)(c) · Ground-fault protection on job sites
Serious$2,842$2,842Jul 1, 2019Final
Citation 1, item 1b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Jul 1, 2019Final
Citation 1, item 2
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$2,842$2,842Jul 1, 2019Final
Citation 1, item 3a
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Serious$1,705$1,705Jul 1, 2019Final
Citation 1, item 3b
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$0$0Jul 1, 2019Final
Citation 1, item 4
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$1,705$1,705Jul 1, 2019Final
Citation 1, item 5a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$3,978$3,978Jul 1, 2019Final
Citation 1, item 5b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Jul 1, 2019Final
Citation 1, item 5c
29 CFR 1926.602(c)(1)(ii) · Earthmovers and forklifts in construction
Serious$0$0Jul 1, 2019Final
Citation 1, item 6a
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$3,978$3,978Jul 1, 2019Final
Citation 1, item 6b
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$0$0Jul 1, 2019Final
Citation 1, item 7
29 CFR 1926.454(b) · Scaffold training
Serious$3,978$3,978Jul 1, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(iii)(c)

(C) Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, shall be visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective shall not be used until repaired.

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.602 · Earthmovers and forklifts in construction

Other framing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.