Juan Jesus Ramirez Cedano: OSHA inspections and violations

Mount Dora, Florida · Masonry Contractors · NAICS 238140

1inspections
4citation items
$4,839current penalties
Nov 7, 2023last inspection

OSHA inspectors have visited Juan Jesus Ramirez Cedano in Florida one time.

It opened on Nov 7, 2023, in Mount Dora and is still open.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $4,839 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Juan Jesus Ramirez Cedano averages $4,839 across 1 cited inspection.

Juan Jesus Ramirez Cedano: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Juan Jesus Ramirez Cedano and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347087538 OPENED NOV 7, 2023Open

Unprogrammed other · Partial · Safety · 4 employees at the site · Open

18660 Us Highway 441, Mount Dora, FL 32757 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$4,839$4,839Jan 25, 2024Final
Citation 1, item 1b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Jan 25, 2024Final
Citation 1, item 1c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Jan 25, 2024Final
Citation 1, item 1d
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Jan 25, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.