OSHA SearchOSHA records by employer

Juan Pablo: OSHA inspections and violations

Cumming, Georgia · Roofing Contractors · NAICS 238160

3inspections
7citation items
$19,052current penalties
May 24, 2018last inspection

OSHA has inspected Juan Pablo 3 times in Georgia since 2012.

The latest one began on May 24, 2018 as a planned inspection, in Canton.

Those inspections ended with 7 citation items: 5 serious and 2 repeat.

Penalties were first proposed at $21,252 and now stand at $19,052, 10% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 3 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Juan Pablo averages $2,772 (1 cited inspection).

Juan Pablo: OSHA citation items per year, 2012 to 2018
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

138employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Juan Pablo and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343187688 OPENED MAY 24, 2018Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jun 30, 2022

55,56,57,58 Cherokee Circle, Canton, GA 30115 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,772$2,772May 30, 2018Final
Citation 1, item 1b
29 CFR 1926.502(d)(17) · Fall protection systems
Serious$0$0May 30, 2018Final

Inspection 337724413 OPENED DEC 6, 2012Closed

Planned · Partial · Safety · 3 employees at the site · Closed Mar 9, 2018

Lot #20 Central Garden Court, Smyrna, GA 30080 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$1,760$1,760Jan 30, 2013Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$6,160$6,160Jan 30, 2013Final
Citation 2, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Repeat$6,160$6,160Jan 30, 2013Final

Inspection 335457784 OPENED JUL 26, 2012Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jul 10, 2013

1695 Water Vista Ct., Cumming, GA 30041 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,800$1,400Aug 24, 2012Final
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$1,600$800Aug 24, 2012Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(d)(17)

(17) The attachment point of the body belt shall be located in the center of the wearer's back. The attachment point of the body harness shall be located in the center of the wearer's back near shoulder level, or above the wearer's head.

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.